| Sign In | Join Free | My webtextiles.com |
|
Brand Name : H3C
Model Number : Huawei Switches CE12804S
Place of Origin : Fujian, China
Price : $4,000.00/pieces 1-9 pieces
MOQ : 1 unit
Private Mold : NO
Products Status : Stock, Used, Stock
Ports : ≥ 48
Transmission Rate : 10/100/1000Mbps
Function : LACP, SNMP
Communication Mode : Full-Duplex & Half-Duplex
Switch Capacity : 56 Gb/s
Product Name : Huawei Switches CE12804S
Type : Rack

CE12804S-DC is CE12804S DC Assembly Chassis with Fans.
Figure 1 shows the appearance of CE12804S-DC.
Table 1 shows the Quick Specs.
| Product Code | CE12804S-DC |
| Switching Capacity? (Tbit/s) | 45/ 258 |
| Forwarding Rate? (Mpps) | 17,280 |
| Service Slots | 4 |
| Switching Fabric? Module Slots | 2 |
| LPU slots | 4 (slot IDs: 01 to 04) |
| MPU slots | 2 (slot IDs: 05 to 06) |
| CMU slots | None (monitoring function integrated on the MPU) |
| SFU slots | 2 (slot IDs: 07 to 08) |
| Power slots | 4 (slot IDs: PM1 to PM4) |
| Fan slots | 3 (slot IDs: FAN1 to FAN3) |
Table 2 shows the recommended elements for the CE12804S-DC.
| Model | Description |
| AC power module | |
| PAC-2700WA | 2700W AC Power Supply |
| FE-SFP optical transceiver | |
| SFP-FE-SX-MM1310 | Optical Transceiver, SFP, 100M/155M, Multi-mode Module(1310nm, 2km, LC) |
| eSFP-FE-LX-SM1310 | Optical Transceiver, eSFP, 100M/155M, Single-mode Module(1310nm, 15km, LC) |
| S-SFP-FE-LH40-SM1310 | Optical Transceiver, eSFP, FE, Single-mode Module(1310nm, 40km, LC) |
| GE-SFP optical transceiver | |
| eSFP-GE-SX-MM850 | Optical Transceiver, eSFP, GE, Multi-mode Module(850nm, 0.55km, LC) |
| SFP-GE-LX-SM1310 | Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 10km, LC) |
| S-SFP-GE-LH40-SM1310 | Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 40km, LC) |
| S-SFP-GE-LH40-SM1550 | Optical Transceiver, eSFP, GE, Single-mode Module(1550nm, 40km, LC) |
| 10G-SFP+ optical transceiver | |
| SFP-10G-USR | 10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.1km, LC) |
| OMXD30000 | Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.3km, LC) |
| 40GE CFP optical transceiver | |
| CFP-40G-LR4 | High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,10km,stright LC) |
| CFP-40G-ER4 | High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,40km,stright LC) |
| 40GE QSFP+ optical transceiver | |
| QSFP-40G-eSR4 | 40GBase-eSR4 Optical Transceiver,QSFP+,40G,Multi-mode (850nm,0.3km,MPO)(Connect to four SFP+ Optical Transceiver) |
| QSFP-40G-ER4 | 40GBase-ER4 Optical Transceiver,QSFP+,40G,Single-mode Module (1310nm,40km,LC) |
| 100GE CFP optical transceiver | |
| CFP-100G-SR10 | High Speed Transceiver,CFP,100G,Multimode Module(850nm,10*10G,0.1km,MPO) |
| CFP-100G-LR4 | CFP, 100G, Single-mode Module(1310nm band,4*25G,10km,stright LC) |
| CFP-100G-ER4 | High Speed Transceiver,CFP,100G,Single-mode Module(1310nm band,4*25G,40km,stright LC) |
| GE copper transceiver | |
| SFP-1000BaseT | Electrical Transceiver,SFP,GE,Electrical Interface Module(100m,RJ45) |
| 100GE interface card | |
| CE-L12CF-EG | 12-Port-100GE Interface Card(EG,CFP2) |
| CE-L08CC-EC | 8-Port-100G Interface Card(EC,CXP) |
| 10GE interface card | |
| CE-L48XT-EC | Huawei 48-port 100M/1000M/10G Base-T Interface Card(EC,RJ45) CE-L48XT-EC |
| CE-L48XS-EC | 48-Port-10GE Interface Card(EC,SFP+) |
| 40GE interface card | |
| CE-L24LQ-EC1 | 24-Port-40G Interface Card(EC1,QSFP+) |
| CE-L12LQ-EF | 12-Port-40G Interface Card(EF,QSFP+) |
| Firewall module | |
| CE-FWA | Huawei CE12800 NGFW Module A CE-FWA, with HW General Security Platform Software |
| GE interface card | |
| CE-L48GT-ED | 48-Port 10/100/1000BASE-T Interface Card(ED,RJ45) |
| CE-L48GS-ED | 48-Port 100/1000BASE-X Interface Card(ED,SFP) |
Table 3 shows the comparison of CE12804A-B01 and CE12804S-DC.
| Product Code | CE12804S-DC | CE12804A-B01 |
| Switching Capacity? (Tbit/s) | 45/ 258 | 45/ 258 |
| Forwarding Rate? (Mpps) | 17,280 | 17,280 |
| Service Slots | 4 | 4 |
| Switching Fabric? Module Slots | 2 | 6 |
| LPU slots | 4 (slot IDs: 01 to 04) | 4 (slot IDs: 01 to 04) |
| MPU slots | 2 (slot IDs: 05 to 06) | 2 (slot IDs: 05 to 06) |
| CMU slots | None (monitoring function integrated on the MPU) | 2 (slot IDs: 07 to 08) |
| SFU slots | 2 (slot IDs: 07 to 08) | 6 (slot IDs: 09 to 14) |
| Power slots | 4 (slot IDs: PM1 to PM4) | 4 (slot IDs: PM1 to PM4) |
| Fan slots | 3 (slot IDs: FAN1 to FAN3) | 9 (slot IDs: FAN1 to FAN9) |
CE12804S-DC Specifications | |
| Switching Capacity (Tbit/s) | 45/ 258 |
| Forwarding Rate (Mpps) | 17,280 |
| Service Slots | 4 |
| Switching Fabric Module Slots | 2 |
| Fabric Architecture | Clos architecture, cell switching, VoQ, and distributed large buffer |
| Airflow Design | Strict front-to-back |
| Device Virtualization | Virtual System (VS) |
| Cluster Switch System (CSS)2 | |
| Super Virtual Fabric (SVF)3 | |
| Network Virtualization | M-LAG |
| TRILL | |
| VxLAN routing and bridging | |
| EVPN | |
| QinQ in VXLAN | |
| VM Awareness | Agile Controller |
| Network Convergence | FCoE |
| DCBX, PFC, and ETS | |
| Data Center Interconnect | BGP-EVPN |
| Ethernet Virtual Network (EVN) for inter-DC Layer 2 network interconnections | |
| Programmability | OpenFlow |
| ENP programming | |
| OPS programming | |
| Puppet, Ansible, and OVSDB plug-ins released on open source websites | |
| Linux container for open source and customization programming | |
| Traffic Analysis | NetStream |
| Hardware-based sFlow | |
| VLAN | Adding access, trunk, and hybrid interfaces to VLANs |
| Default VLAN | |
| QinQ | |
| MUX VLAN | |
| GVRP | |
| MAC Address | Dynamic learning and aging of MAC addresses |
| Static, dynamic, and blackhole MAC address entries | |
| Packet filtering based on source MAC addresses | |
| MAC address limiting based on ports and VLANs | |
| IP Routing | IPv4 routing protocols, such as RIP, OSPF, IS-IS, and BGP |
| IPv6 routing protocols, such as RIPng, OSPFv3, ISISv6, and BGP4+ | |
| IP packet fragmentation and reassembling | |
| IPv6 | IPv6 over VXLAN |
| IPv6 over IPv4 | |
| IPv6 Neighbor Discovery (ND) | |
| Path MTU Discovery (PMTU) | |
| TCP6, ping IPv6, tracert IPv6, socket IPv6, UDP6, and Raw IP6 | |
| Multicast | IGMP, PIM-SM, PIM-DM, MSDP, and MBGP |
| IGMP snooping | |
| IGMP proxy | |
| Fast leave of multicast member interfaces | |
| Multicast traffic suppression | |
| Multicast VLAN | |
| MPLS | Basic MPLS functions |
| MPLS VPN/VPLS/VPLS over GRE | |
| Reliability | Link Aggregation Control Protocol (LACP) |
| STP, RSTP, VBST, and MSTP | |
| BPDU protection, root protection, and loop protection | |
| Smart Link and multi-instance | |
| Device Link Detection Protocol (DLDP) | |
| Ethernet Ring Protection Switching (ERPS, G.8032) | |
| Hardware-based Bi-directional Forwarding Detection (BFD) | |
| VRRP, VRRP load balancing, and BFD for VRRP | |
| BFD for BGP/IS-IS/OSPF/Static route | |
| In-Service Software Upgrade (ISSU) | |
| Segment Routing (SR) | |
| QoS | Traffic classification based on Layer 2, Layer 3, Layer 4, and priority information |
| Actions include ACL, CAR, and re-marking | |
| Queue scheduling modes such as PQ, WFQ, and PQ + WRR | |
| Congestion avoidance mechanisms, including WRED and tail drop | |
| Traffic shaping | |
| O&M | IEEE 1588v2 |
| Packet Conservation Algorithm for Internet (iPCA) | |
| Dynamic Load Balancing (DLB) | |
| Dynamic Packet Prioritization (DPP) | |
| Network-wide path detection | |
| Microsecond-level buffer detection | |
| Configuration and Maintenance | Console, Telnet, and SSH terminals |
| Network management protocols, such as SNMPv1/v2c/v3 | |
| File upload and download through FTP and TFTP | |
| BootROM upgrade and remote upgrade | |
| Hot patches | |
| User operation logs | |
| Zero-Touch Provisioning (ZTP) | |
| Security and Management | 802.1x authentication |
| RADIUS and HWTACACS authentication for login users | |
| Command line authority control based on user levels, preventing unauthorized users from using commands | |
| Defense against MAC address attacks, broadcast storms, and heavy-traffic attacks | |
| Ping and traceroute | |
| Remote Network Monitoring (RMON) | |
| Dimensions (W x D x H, mm) | 442 x 620 x 352.8 (8U) |
| Chassis Weight (empty) | < 60 kg (132 lb) |
| Operating Voltage | AC: 90V to 290V DC: -38.4V to -72V HVDC: 240V |
| Max. Power Supply | 6,000W |
|
|
Huawei CE12804S Data Center Core Enterprise Campus Switches designed with ≥ 48 Ports Images |